_img_banner

Trusted by many of the worlds greatest companies

WHY AN ATEX VACUUM?

The European Union adopted two European directives in regard to health and safety, known as ATEX 2014/34/UE (also ATEX 114) and ATEX 99/92/CE (also ATEX 137 or ATEX 153), concerning the risk of the existence of potentially explosives atmospheres.

• 2014/34/EU for the regulation of those devices to be used in zones where a risk of explosion exists; the directive points at those manufacturers of equipment intended for use in areas with potentially explosive atmospheres and at an obligation to certify these products; Directive 94/9/CE was cancelled and replaced effectively from 20 April 2016;

• 99/92/CE for the workers safety and health in explosive atmospheres; it is applied to those environments where a risk of explosion exists, where installations and certified tooling is used and it is consequently addressed to the users.

HOW A MAXVAC ATEX VACUUM IS MADE

M CLASS ANTISTATIC FILTER LARGE SURFACE STAINLESS STEEL AISI 304 VACUUM BREAKER HEPA H14 STANDARD ON Z20/21 UNITS SAFETY VALVE ELECTRICAL BOARD IP 65 ABSOLUTE FILTER FILTER CLEANING SYSTEM ALL COMPONENTS ARE GROUNDED SIDE CHANNEL BLOWER

ATEX ZONES CLASSIFICATION

ATEX zones classify the risk of potentially explosive
atmospheres and require ATEX-certified industrial vacuums for safety:

Zone 20 (Z20): Combustible dust continuously present or for extended periods.
Zone 21 (Z21): Combustible dust likely to occur occasionally during normal operation.
Zone 22 (Z22): Combustible dust infrequently present and short-lived.

Zone 0 (Z0): Flammable gas or vapor continuously present or for long periods.
Zone 1 (Z1): Flammable gas or vapor likely to occur during normal operation.
Zone 2 (Z2): Flammable gas or vapor present occasionally and briefly.

DUST GAS 20 0 21 1 22 2 ZONE ZONE ZONE ZONE ZONE ZONE 1D 2D 3D 1G 2G 3G HIGH PROBABILITY OF EXPLOSION MEDIUM PROBABILITY OF EXPLOSION LOW PROBABILITY OF EXPLOSION MARKING MARKING MARKING MARKING MARKING MARKING

EXPLOSION PENTAGON

Just like the fire triangle, that represents the flammability conditions (and of consequent explosion), for liquid and gaseous combustibles, it is common to refer to “the explosion pentagon” when it comes to dusts as well as gases, vapours and mists.The five conditions represented in the pentagon of the explosions, and necessary to create the conditions for an explosion are:

  1. Presence of combustible dust
  2. Presence of a combustion agent in the environment
  3. Presence of an ignition source
  4. Delimited environment
DUST & GASS INCREASE OF TEMPERATURE, SPARKS AND OPEN FLAMES CLOSED AREA WHERE THE COMBUSTIBLE CANNOT BE EASILY DISPERSED MIX OF COMBUSTIBLE AND FUEL

ATEX industrial vacuums are intrinsically safe to minimise the risk of explosion, according to the specific requirements of each respective zone.

SV1-430-A45R-Z22

A compact, powerful cleaner with a brushless motor and Atex Marking for hazardous environments. It has a 1.5 HP motor, 230 mBar maximum vacuum, 220 m3/h airflow, and a 45-liter bin capacity. The vacuum operates quietly at 72 dB(A) and features a 50mm inlet and M Class antistatic polyester primary filter.

POWER 1,1 kW
SURFACE 40.000 cm2
CAPACITY 45 Lt

SV1-425-MINI-Z22

A lightweight, compact vacuum designed for hazardous environments. Equipped with a brushless motor, it offers a 1.1 kW power, 230 mBar vacuum, and 220 m3/h airflow. The 45-liter capacity unit operates at 72 dB(A) and utilizes an M Class antistatic polyester filter.

POWER 1,1 kW
SURFACE Up to 22.000 cm2
CAPACITY 45 Lt

SV1-822-MBT-Z22

A powerful vacuum for hazardous environments with a 2.2 kW fan motor, up to 1400 m3/h airflow, and a 65/100-liter bin capacity. It features a 100-150mm inlet, operates at 73 dB(A), and uses an M Class antistatic polyester filter with manual shaker or optional reverse jet cleaning.

POWER 2,2 kW
SURFACE Up to 90.000 cm2
CAPACITY 65 / 100 Lt

SV1-825-MBTH-Z22

A high-capacity vacuum for hazardous environments, featuring a 4 kW fan motor, 2700 m3/h max airflow, and a 65-liter bin. It has a 150-200mm inlet and operates at 77 dB(A). Equipped with an M Class antistatic polyester filter, it offers manual shaker or optional reverse jet cleaning. Optional features include stainless steel bin, HEPA 13 filter, and antistatic PTFE filter.

POWER 4 kW
SURFACE Up to 160.000 cm2
CAPACITY 65 Lt

SV1-930-Z22

A versatile vacuum for hazardous environments, utilizing a Venturi Pipe with a required air flow of 2500 Lt/min at 6-8 Bar pressure. It offers a 500 mBar maximum vacuum and 250 m3/h airflow. This 45-liter capacity unit features a 70mm inlet, operates at 73 dB(A), and includes an M Class antistatic polyester filter with manual shaker cleaning. An optional absolute H14 fiberglass filter is available.

SUCTION TYPE Venturi Pipe
SURFACE 22.000 cm2
CAPACITY 45 Lt

SV1-970-Z2/Z22

Designed for hazardous environments and utilizes a Venturi Pipe with a required pressure of 6-8 bars. It offers a 500 mm/H2O maximum vacuum and 480 m3/h airflow. This unit features an 80mm inlet, operates at 70 dB(A), and has a 65/100-liter bin capacity. Equipped with an M Class antistatic polyester filter, it provides manual shaker cleaning with an optional SP filter cleaning and H14 fiberglass media.

SUCTION TYPE Venturi Pipe
SURFACE Up to 28.000 cm2
CAPACITY 65 / 100 Lt

SV1-425/825-MBSV-Z22

These vacuums are designed for hazardous environments, utilize side channel blowers with 1.8 kW (2.4 HP) and 3 kW (4 HP) power. They offer maximum vacuums of 230 mBar and 270 mBar, with airflows of 280 m3/h and 350 m3/h.

POWER 1,8 - 3 kW
SURFACE Up to 90.000 cm2
CAPACITY 45 Lt

SUITABLE ACCESSORIES

An accessory, to be used in an atex classified environment, must be able to electrically conduct all electrostatic charges that may arise during the suction process. The resistivity, expressed in 10 Ω, of the materials used in the accessories characterizes their ability to discharge electrostatic energy.

FLEXIBLE TUBES

Electroconductive "EVA" Ø 40 - Ø 50 mm

Made of permanent electroconductive material ≤10 Ω Ohm / meter.Lightweighted, extremely flexible even at low temperatures.Resistant to hydrolysis, microbiotic attacks and UV rays

Antistatic Polyurethane Ø 40 - Ø 50 - Ø 70 - Ø 100 mm

Made of antistatic polyurethane with copper helicoid ≤10 Ω Ohm / meter, in accordance with ATEX 2014/34 / EU (1999/92 / EC).Its resistance makes it ideal for applications in the ATEX area, where the material to be vacuumed is abrasive and / or aggressive.

ANTISTATIC ACCESSORIES

“S” Handgrip for floor brush

Sturdy metal “S” pipe for 70 mm diameter floor brush.

Antistatic floor brush with brass bristles strips

Antistatic floor brush with brass bristles for A use with ATEX certified vacuums 40 - 50 mm ø.

Probe pipe with handle

Galvanised steel suction pipe 50 mm diameter.

Extension pipe with handle

70 mm diameter probe pipe with inner liner for the passage of the air. Useful for vacuuming piles of material.

Scraping suction pipe

Galvanised steel scraping suction pipe 40 - 50 mm ø.

Brush with antistatic brass bristles strips

Round suction brush with brass bristles for 40 - 50 mm ø flexible hose. Conductive accessory, convenient for use with ATEX industrial vacuums.

Brush with antistatic brass bristles strips

Round suction brush with brass bristles for 40 - 50 mm ø flexible hose. Conductive accessory, convenient for use with ATEX industrial vacuums.

Antistatic rubber conic section with metal fitting

Antistatic conic section with metal fitting for 40 - 50 - 70 mm ø flexible hose.

Antistatic flat pipe

Galvanised steel suction NOZZLE. Handy and durable. Conductive and therefore suitable for working with ATEX certified machines.ø 40 - ø 50 - ø 70 mm flexible hose fitting.

Antistatic rubber flat pipe with metal fitting

Suction lance in special oil-proof rubber, carbon-loaded and therefore conductive, suitable for working with ATEX certified machines. 40 - 50 mm ø flexible hose fitting.

Antistatic rubber conic bend with metal fitting

Suction cone in special oil-proof rubber, carbon-loaded and therefore conductive, suitable for working with ATEX certified machines.The cone can be cut in various marked points in order to increase the suction section.40 - 50 mm ø flexible hose fitting.

Antistatic sweeper nozzle with metal fitting

Suction cup in special oil-proof rubber, carbon-loaded and therefore conductive, suitable for working with ATEX certified machines. 40 - 50 mm ø flexible hose fitting.

Unlock Your Team's Potential

Are you intrigued by the powerful capabilities and features of the MAXVAC ATEX Range?

We're here to help you harness the unmatched performance, durability, and efficiency of these industrial floor preparation vacuums for your demanding projects. Our team of experts is eager to assist you in selecting the ideal solution tailored to your specific needs.

You can also reach us by phone on